2LK/2LN/2LM/2LC
1-3-106
U199 Displaying fuser heater temperature
Description
Displays the detected fuser temperature.
Purpose
To check the fuser temperature.
Method
1. Press the start key. The fuser temperature is displayed.
Completion
Press the stop key. The screen for selecting a maintenance mode No. is displayed.
U200 Turning all LEDs on
Description
Turns all the LEDs on the operation panel on.
Purpose
To check if all the LEDs on the operation panel light.
Method
1. Press the start key.
2. Select [Execute].
3. Press the start key.All the LEDs on the operation panel light.
4. Press the stop key. The LEDs turns off.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Heat Roller Edge1 Heat roller edge temperature (°C)
Heat Roller Edge2 Heat roller edge temperature (°C)
Heat Roller Center Heat roller center temperature (°C)
Press Roller Center Press roller center temperature (°C)