2LK/2LN/2LM/2LC
1-3-112
U206 Setting: [Price]
1. Select the item to be set.
Initial setting: Off
2. Select the paper size to be set.
3. Change the setting value using the +/- keys.
In 10-yen increments
Value of 0 allows non-restricted copying. (At a periodic maintenance, etc.)
4. Press the start key. The value is set.
5. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
U207 Checking the operation panel keys
Description
Checks operation of the operation panel keys.
Purpose
To check operation of all the keys and LEDs on the operation panel.
Method
1. Press the start key. The screen for executing is displayed.
2. [Count0] is displayed and the left most LED on the operation panel lights.
3. As the keys lined up in the same line as the lit indicator are pressed in the order from the top
to the bottom, the figure shown on the touch panel increases in increments of 1. When all the
keys in that line are pressed and if there are any LEDs corresponding to the keys in the line
on the immediate right, the top LED in that line will light.
4. When all the keys on the operation panel have been pressed, all the LEDs light for up to 10
seconds.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
B/W Black & White
CMY Single color C, M, Y
RGB Single color R, G, B
Full Color Full color
Display Description
Setting
range
Initial
setting
B/W CMY/RGB
Full Color
A3-Ledger A3/Ledger size 0 to 300 10 100
B4 B4 size 0 to 300 10 50
Card Post card 0 to 300 10 30
Other Other 0 to 300 10 50