2LK/2LN/2LM/2LC
1-3-159
U411 7. Press the start key. Auto adjustment starts.
* : When automatic adjustment has normally completed, [OK] is displayed. If a problem
occurs during auto adjustment, error code is displayed and operation stops. Should this
happen, determine the details of the problem and repeat the procedure from the begin-
ning.
Method: [DP FaceDown (Chart1)]
To manually enter the target value
1. Enter the target values which are shown on the specified original (P/N: 7505000005) execut-
ing maintenance item U425. Set a specified original (P/N: 7505000005) on the DP face
down.
2. Enter maintenance item U411.
3. Select [Target].
4. Select [U425] and press the start key.
5. Select [DP FaceDown (Chart1)].
6. Select [All].
To manually enter the target value
1. Set a specified original (P/N: 7505000005) on the DP face down.
2. Enter maintenance item U411.
3. Select [Target].
4. Select [Auto] and press the start key.
5. Select [DP FaceDown (Chart1)].
6. Select [All].
7. Press the start key. Auto adjustment starts.
* : When automatic adjustment has normally completed, [OK] is displayed. If a problem
occurs during auto adjustment, error code is displayed and operation stops. Should this
happen, determine the details of the problem and repeat the procedure from the begin-
ning.
Item No. Description
Display Description
All Executing the adjustment in the DP scanning section (second
side) for magnification, leading edge timing, center line, MTF
filter, input gamma and matrix