EasyManua.ls Logo

Kyocera TASKalfa 5550ci - Page 271

Kyocera TASKalfa 5550ci
936 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2LK/2LN/2LM/2LC-2
1-3-177
U464 Setting: [Leaving Time]
1. Change the setting value using the +/- keys or numeric keys.
2. Press the start key. The value is set.
Setting: [Driving Time]
1. Change the setting value using the +/- keys.
2. Press the start key. The value is set.
Setting: [Timing]
1. Change the setting value using the +/- keys.
2. Press the start key. The value is set.
Setting: [Target Value]
1. Select the item.
2. Change the setting value using the +/- keys or numeric keys.
3. Press the start key. The value is set.
Item No. Description
Display Description Setting range
Initial
setting
Time(min) Setting the standard time of sleep mode 0 to 480 (min) 480
Display Description Setting range
Initial
setting
Time(sec) Setting the drive standard time 300 to 3000 (s) 300
Display Description Setting range
Initial
setting
Time(sec) Setting the drive standard time of con-
tinuous print
300 to 3600 (s) 3600
Display Description
Setting
range
Initial setting
30ppm 35ppm 45ppm 55ppm
Thick-
ness(C)
Toner thick layer calibration
(cyan)
0 to 1000 890 890 890 890
Thick-
ness(M)
Toner thick layer calibration
(magenta)
0 to 1000 910 910 910 910
Thick-
ness(Y)
Toner thick layer calibration
(yellow)
0 to 1000 910 910 910 910
Thick-
ness(K)
Bias for addition in toner thick
layer calibration (black)
0 to 1000 740 790 760 760
Gamma(C) Light amount calibration
(cyan)
0 to 500 320 320 320 320
Gamma(M) Light amount calibration
(magenta)
0 to 500 320 320 320 320
Gamma(Y) Light amount calibration
(yellow)
0 to 500 300 300 300 300
Gamma(K) Light amount calibration
(black)
0 to 500 350 350 350 350