Loading...
2LK/2LN/2LM/2LC-2
1-4-89
9070 Communication error
between DP and SHD
A communication error is
detected.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
DPSHD PWB (YC1) and DP main PWB
(YC10)
Defective DPSHD
PWB.
Replace the DPSHD PWB and check for
correct operation.
9080 LED fault detection
When the power supply is
turned on, the peak value of
LED is 80hex or less.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
CIS and DPSHD PWB (YC1)
DPSHD PWB (YC1) and DP main PWB
(YC10)
Defective CIS. Replace CIS and check for correct opera-
tion.
Defective DPSHD
PWB.
Replace the DPSHD PWB and check for
correct operation.
9100 Coin vender control PWB
error
Communication error has
been detected at the coin mec
of the coin vender control
PWB.
Defective coin
vender control
PWB.
Replace the coin mec.
9110 Coin vender error
Communication error has
been detected in connection
with the coin mec and the
rejector.
Rejector installed
incorrectly.
Check the rejector is properly installed and,
if not, perform the corrective action.
Defective rejector. Replace the rejector.
9120 Sensor error in coin vender
change (Yen 10)
Change is empty despite
change is enough.
Coin jam in the
change tube
Check visually and remedy.
Poor contact in the
connector.
Check if the change empty sensor is intact.
Defective change
empty sensor.
Replace the coin mec.
Defective coin
vender control
PWB.
Replace the coin mec.