9 Technical data (to DIN 58966)
Common technical data
E 200
Ambient temperature range °C 5 to 40
Settin
resolution °C 0.1/ 0.01
Indication resolution °C 0.05
Indication accurac
°C ± 0
2 °C additive re-calibration ➁
Tem
erature control ± °C 0
01
Safet
features ➀ FL
Additional functions LCD Display two line
Power
consumption
230 V;50/60 Hz
115 V; 60 Hz
100 V:50/60 Hz
kW 2.3
1.4
1.1
➀ FL: suitable for flammable and non-flammable liquids; NFL: only suitable for non-flammable liquids
➁ ➾ Section 7.2. last item
Immersion thermostats
E 200
Operating temperature range
➀ °
" with water cooling °C 20 to 200
Operating temperature range ➁ °C -20 to 200
Interface RS 232,. RS 485
Heater
power
230 V; 50/60 Hz
115 V; 60 Hz
100 V; 50/60 Hz
2.25
1.3
1.0
Pump type pressure pump with choice of 5 output steps
Max. discharge pressure
➂ bar 0.4
Max. flow rate➂ l/min 20
Pump connections mm nipples 13 mm dia.
Bath depth ➃ mm min 150
Usable depth ➃ mm min 100
Overall size (WxD) mm 125x133
Height (H) mm 315
Weight kg 3
Ref. No. 230 V; 50/60 Hz
115 V; 60 Hz
100 V; 50/ 60Hz
LCE 0222
LCE 4222
LCE 6222
➀ at pump output step 1 ➁ with additional cooling
➂ at pump output step 5 ➃ baths ➾ section 10. Accessories
Bath/Circulation thermostats