6
G6A Low Signal Relay
G
6
A
*1. The tests were conducted at an ambient temperature of 23ºC.
*2. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary
according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use.
●Electrical Durability Test *1 ●Contact Reliability Test *1, *2
●Mutual Magnetic Interference
G6A-274P G6A-274P
●External Magnetic Interference
G6AK-274P
(Average value) G6AK-274P (Average value) G6AK-274P (Average value)
max.
min.
max.
min.
max.
max.
min.
min.
80
70
60
50
40
30
20
10
100
70
50
30
On the basis of rated voltage (%)
Contact resistance (mW)
Must operate voltage
1 3 5 500100503010
NO contact NC contact
Operating frequency (×10
4
operations)
Must release voltage
Sample: G6A-274P
Number of Relays: 10 pcs
Test conditions: 125 VAC 0.5 A (Resistive load)
Switching frequency: 1,800 operations/h
NO contact
NC contact
Sample: G6A-274P 5 VDC
Number of Relays: 10 pcs
Test conditions: Load 10 m VDC
10 mA (Resistive load)
Switching frequency:
7,200 operations/h
max.
min.
max.
min.
0 3 5 10 30 50 100 300 1,000 3,000
1,000
500
300
100
50
30
10
Operating frequency (×10
4
operations)
Contact resistance (mW)
+10
+5
0
−5
−10
Change rate on the
basis of initial value (%)
Change rate on the
basis of initial value (%)
Average value
Average value
TestInitial stage
+10
+5
0
−5
−10
TestInitial stage
Must operate voltage
Must release voltage
De-
energized
De-
energized
Sample
Energized
Energized
Sample
2.54 mm
X
X
X
X
2.54 mm
+10
+5
0
−5
−10
Change rate on the
basis of initial value (%)
Change rate on the
basis of initial value (%)
Test
+10
+5
0
−5
−10
Test
Sample
Sample
X
X
X
X
Must operate voltage
Must release voltage
Average value
Average value
Initial stage
Initial stage
Energized
De-
energized
Sample: G6AK-274P 5 VDC
Number of Relays: 10 pcs
+20
+10
0
−10
−20
−4,000 −2,400 −800 0 800 2,400 4,000
−3,200 −1,600 1,600 3,200
Set voltage
Reset voltage
NS
SN
External magnetic field (A/m)
Rate of variability (%)
Sample: G6AK-274P 5 VDC
Number of Relays: 10 pcs
+20
+10
0
−10
−20
−4,000 −2,400 −800 0 800 2,400 4,000
External magnetic field (A/m)
−3,200 −1,600 1,600 3,200
Set voltage
Reset voltage
SN
NS
Rate of variability (%)
Sample: G6AK-274P 5 VDC
Number of Relays: 10 pcs
+20
+10
0
−10
−20
−4,000 −2,400 −800 0 800 2,400 4,000
External magnetic field (A/m)
Rate of variability (%)
−3,200 −1,600 1,600 3,200
SN
NS
Set voltage
Reset voltage