DMA882S Digital Stepper Drive User Manual
Page | 2
2.2 Environment
Natural Cooling or Forced cooling
Avoid dust, oil fog and corrosive gases
0°C - 65°C (32°F - 149°F)
0°C - 50°C (32°F - 122°F)
-20°C - 65°C (-4°F - 149°F)
2.3 Mechanical Specifications
(unit: mm [1inch=25.4mm])
Side mounting recommended for better heat dissipation
2.4 Elimination of Heat
DMA882S reliable working temperature should be < 60℃ (140°F)
It is recommended to use automatic idle-current mode to reduce motor heating. That means set the SW4 pin of
DIP switch at “OFF” position.
It is recommended to mount the drive vertically to maximize heat sink area. Use forced cooling method to cool if
necessary.
Figure 1: Mechanical specifications