CÉLIANE TECHNICAL GUIDE
SCS BUS SYSTEM
III-95
CABLE 5739 99
For video system, Legrand produces a dedicated cable, made
of two twisted conductors with a section of 0.50 mm
2
each. This
cable ensures the best performance of the video system (greater
distance between Entrance Panel and Handset, when compared
to other cables).
In addition, differently to standard cables, which are not suitable
for underground installation even when inside ducts, this cable
may be installed underground provided that it is protected by
suitable ducts.
WARNINGS:
although the construction of the white cable, 5739 99 guarantees 300/500V electric insulation, it does
not however guarantee immunity from disturbances that may occur if this cable is installed inside the
same ducts as 230V power supply cables.
These types of installations are not recommended.
WHITE CABLE for Video Handset, HOME VIDEO SURVEILLANCE and Sound System
CABLE 492 31 AND 492 32
This cable has been designed for the installation of BUS systems
for the following applications: Automation, Temperature Control
and Burglar alarm. This cable can be used for the distribution
of the power supply and operating signals. With the 300/500V
insulated BUS cable, and the terminal protection cover, with
which all devices are fitted, the systems may also be installed in
the same boxes and ducts as the electric power supply lines (230
Vac).
GREY CABLE for Automation, Temperature control and Burglar alarm
TECHNICAL FEATURES
SCS sheathed pair made up of 2 flexible wires, sheated,
unshielded;
Insulation voltage: 300 – 500 V.
Coil length
White 5739 99 200 m
Grey
0492 31 100 m
0492 32 500 m
PLUG-IN TERMINAL
The devices connected to the SCS BUS using a screw plug-in
terminal. With the plug-in terminal, it is possible to wire the
system in advance and connect the devices just before the
running test.
screw plug-in terminal

Related product manuals