Example of lighting system
and management of rolling shutters
Distribution of components inside the individual rooms
Living room
1 general lighting control (1) +1 general automation control (36) + Touch Screen Control (34)
1 ceiling light point
11
controlled from 4 points (2-5-6-7)
1 light point
12
controlled from one point (3) with dimmer
Bedroom/Studio
1 ceiling light point
21
controlled from 2 points (8-11) with dimmer
1 light point for bedside table lamp
22
including an actuator and a controlled socket, controlled from 1 point (10)
1 motorised rolling shutter
23
controlled from 2 points (38-39)
Kitchen
1 ceiling light point
31
controlled from 1 point (12)
1 motorised rolling shutter
32
controlled from 2 points (41-42)
Corridor
2 ceiling light points
81
controlled from 5 points (29-30-31-32-33)
Bathroom
1 ceiling light point
71
controlled from 1 point (25) with activation of exhaust fan
1 wall light point
72
controlled from 1 point (28)
Bedroom
1 ceiling light point
41
controlled from 3 points (13-15-16) with dimmer
2 light points for bedside table lamp
42
43
including an actuator and controlled sockets, each controlled from 1 point respectively (17-18)
1 motorised rolling shutter 44 controlled from 2 points
44
controlled from 2 points (45-46)
1 scenario control unit (43)
Second bathroom
1 ceiling light point
51
controlled from 1 point (19)
1 wall light point
52
controlled from 1 point (20)
1 motorised rolling shutter
53
controlled from 1 point (48)
Second bedroom
1 ceiling light point
61
controlled from 2 points (21-22)
1 light point for bedside table lamp
62
including an actuator and a controlled socket, controlled from point (23)
1 motorised rolling shutter
64
controlled from 2 points (50-51)
Home automation panel DIN modules
1 SCS power supply 8