Thermostat with display
Installer manual
5.2.2 Automatic function in Comfort, Eco, and Protection mode
Automatic changeover depends on the operating mode selected: comfort, eco, or protection.
In this case, the heating and cooling ranges must have been previously set in the corresponding
modes (see paragraph 6.3).
Therefore, two parameters for each mode must be set: a high set-point to set in the cooling func-
tion, and a low set-point to set in heating mode.
5 Functions and operating modes
Example of temperature range settings
The above example indicates the temperature set-point pairs for Eco mode and Comfort mode.
The cooling system will activate when the temperature exceeds the upper set-point, while the
heating system will activate when the temperature falls below the lower set-point.
COOLING
RANGE
HEATING
RANGE
32°
22°
24°
14°
SET-POINT ECO
SET-POINT ECO 18°
28°
COOLING
HEATING
32°
22°
24°
14°
SET-POINT COMFORT
SET-POINT COMFORT
21°
25°
COOLING
HEATING
COOLING
RANGE
HEATING
RANGE
ECO Mode COMFORT mode
COOLING
RANGE
HEATING
RANGE
32°
22°
24°
14°
SET-POINT ECO
SET-POINT ECO 18°
28°
COOLING
HEATING
32°
22°
24°
14°
SET-POINT COMFORT
SET-POINT COMFORT
21°
25°
COOLING
HEATING
COOLING
RANGE
HEATING
RANGE

Related product manuals