The XT2 system may be fitted with optional PIR movement detectors in each flat to monitor the resident’s activity.
Up to 3 Activity Start/End Time periods can be set per flat to operate on a daily basis.
The Activity Period is a smaller window of time (5 to 720 mins) which can be set to split each start/end time into
smaller inactivity reporting periods.
If during an active monitoring time, an activity period elapses where there has been no resident activity then an
inactivity alarm will be signalled for that resident. This will be repeated for each interval within an active monitoring
time. If the Activity Period is not set (0) then no resident activity will only be reported at the end of the monitoring
time. Note: Activity Monitoring can be temporarily disabled by selecting “Away Mode” on the resident’s intercom.
From Settings on the Home page, enter the Manager (or Engineer) password, then press the Programming button.
Select the Activity Monitoring option from the tabs along the bottom of the screen.
Press Flat ID and use the on-screen keypad to enter the flat number required.
Press the Request button to view the current Activity Monitoring settings for the flat number selected.
Press Activity Period and choose from the options listed (5 to 720 mins);
Press Start/End Time 1 and use the keypad to enter the start and end times for activity monitoring period 1;
Press Start/End Time 2 and use the keypad to enter the start and end times for activity monitoring period 2.
Press Start/End Time 3 and use the keypad to enter the start and end times for activity monitoring period 3.
If an Activity period is not required the Start/End Times should be set as 00:00.