FlexLine/FlexLine plus, 16
Peg Survey
Measure points
step-by-step
Next step
After each set the Tolerances Met, or the Out of Tolerance screen displays.
Step Description
1. Enter the reflector height (hr:) for the backsight point, if required.
2. Aim at backsight point and press Meas Pt.
3. Depending on the measurement sequence selected, enter a desired
backsight or foresight point ID (PtID:). Cont saves the point ID and
proceeds to the measurement screen.
4. Enter the reflector height (hr:) for the point, if required.
5. Aim at target point and press Meas Pt.
6. Decide whether to measure an additional point:
• No Repeat steps 2. and 5. until all sets are measured.
• Yes Repeat steps 3. to 5. with a new point.
)
A maximum of 7 additional points can be measured.
7. If the tolerances after a set are not met, the user has the option to continue
with the measurements or reject the data.
• Reject to reject the measurements and remeasure the set again.
• Accept to accept the result and continue with the next set.