CHA161853 MODELS (TABLE 8)
Electric Heat
Model No.
&
Net Wei
g
ht
No.
of
Ste
p
s
Volts
Input
kw
Input
Btuh
Output
*Total Unit &
Electric Heat
Minimum Circuit
Ampacity
&
Net
Weight
Steps
p
p
p
3 hp 5 hp
208 11.3 38,600 86.0 92.0
ECH16
1
220 12.6 43,000
ECH16
18515
208/230v
1
230 13.5 46,100
86.0 92.0
208/230v
(24H27)
460v
240 15.0 51,200
()
460v
(24H32)
(47 lbs )
440 12.6 43,000
()
(47 lbs.)
1
460 13.8 46,100
44.0 47.0
480 15.0 51,200
208 22.5 76,800 92.0 99.0
ECH16
**2
220 25.2 86,000
ECH16
185/30030
208/230v
**2
230 27.5 93,900
103.0 110.0
208/230v
(24H28)
460v
240 30.0 120,400
()
460v
(24H33)
(51 lbs )
440 25.2 86,000
()
(51 lbs.)
1
460 27.5 93,900
52.0 55.0
480 30.0 102,400
208 33.8 115,300 131.0 139.0
ECH16
**3
220 37.8 129,000
ECH16
185/30045
208/230v
**3
230 41.3 141,000
148.0 155.0
208/230v
(24H29)
460v
240 45.0 153,600
()
460v
(24H34)
(62 lbs )
440 37.8 129,000
()
(62 lbs.)
**2
460 41.3 141,000
74.0 78.0
480 45.0 153,600
208 45.0 153,600 170.0 177.0
ECH16
**4
220 50.4 172,000
ECH16
185/30060
208/230v
**4
230 55.1 188,000
193.0 200.0
208/230v
(24H30)
460v
240 60.0 204,800
()
460v
(24H35)
(67 lbs )
440 50.4 172,000
()
(67 lbs.)
**2
460 55.1 188,000
97.0 100.0
480 60.0 204,800
ECH16
185/300 75
440 63.0 215,000
185/30075
460v
(24H36)
**3
460 68.9 235,100
119.0 123.0
(24H36)
(88 lbs.)
480 75.0 255,900
*Refer to National Electrical Code manual to determine wire, fuse and disconnect size re
quirements. Use wires suitable for at least 167°F.
**May be used with two stage control.
NOTE  Fuse block must be ordered extra. Factory installed heaters will have the
fuse block factory installed. Fuse block must be installed in field installed
heaters. See Optional Accessories tables.
CHA162553 MODELS (TABLE 9)
Electric Heat
Model No.
& Net Wei
g
ht
No.
of
Ste
p
s
Volts
Input
kw
Input
Btuh
Output
*Total Unit &
Electric Heat
Minimum Circuit
Ampacity
&
Net
Weight
Steps
5 hp 7.5hp
208 22.5 76,800 110.0 117.0
ECH16
**2
220 25.2 86,000
ECH16
185/30030
208/230v
**2
230 27.5 93,900
110.0 118.0
208/230v
(24H28)
460v
240 30.0 102,400
()
460v
(24H33)
(51 lbs )
440 25.2 86,000
()
(51 lbs.)
1
460 27.5 93,900
55.0 59.0
480 30.0 104,400
208 33.8 115,300 139.0 148.0
ECH16
**
3
220 37.8 129,000
ECH16
185/30045
208/230v
**3
230 41.3 141,000
155.0 163.0
208/230v
(24H29)
460v
240 45.0 153,600
()
460v
(24H34)
(62 lbs )
440 37.8 129,000
()
(62 lbs.)
**2
460 41.3 141,000
78.0 82.0
480 45.0 153,600
208 45.0 153,600 178.0 187.0
ECH16
**
4
220 50.4 172,000
ECH16
185/30060
208/230v
**4
230 55.1 188,100
200.0 208.0
208/230v
(24H30)
460v
240 60.0 204,800
()
460v
(24H35)
(67 lbs )
440 50.4 172,000
()
(67 lbs.)
**2
460 55.1 188,100
100.0 104.0
480 60.0 204,800
208 56.3 192,200 217.0 226.0
ECH16
275/300 75
**
5
220 63.0 215,000
275/30075
208/230v
(24H31)
**5
230 68.9 235,000
245.0 253.0
(24H31)
ECH16
185/300 75
240 75.0 255,900
185/30075
460v
(24H36)
440 63.0 215,000
(24
H
36)
(88 lbs.)
**3
460 68.9 235,000
123.0 127.0
480 75.0 255,900
ECH16
275/300 90
440 75.6 258,000
275/30090
460v
(24H37)
**3
460 82.7 282,000
145.0 150.0
(24H37)
(92 lbs.)
480 90.0 307,100
*Refer to National Electrical Code manual to determine wire, fuse and disconnect size re
quirements. Use wires suitable for at least 167°F.
**May be used with two stage control.
NOTE  Fuse block must be ordered extra. Factory installed heaters will have the
fuse block factory installed. Fuse block must be installed in field installed
heaters. See Optional Accessories tables.