DIAGRAM REFERENCE LEGEND
– A1 -2-3-4 AIR SOCK CONTROL
– B1 EXTERNAL AIR THERMOSTAT – KE1 -2 -3 HEATER -E1 - E2 - E3 CO NTACT OR
– B2 SMOKE DETECTION HEAD
– B3 RC CIRCUI T
– B4 - B5 GAS MANIFOLD IONISATION PROBE – KM1 - KM 2 BLOWER FAN MOTOR -MS1 - MS2 CONTACTOR
– B6 - B7 GAS MANIFOLD IGNITION ELECTRODE
– B1 0 AIR PRESSURE SWITCH – KM5 - KM 6 EXTRACTION FAN MOTOR -ME1 - ME2 CONTACTOR
– B1 1 WATER FLOW RATE CONTROLLER
– B1 3 CL OGG ED AI R F ILTER PRESSURE SWIT CH / AIR F LOW RAT E
– B1 4 HO T WATER CO IL ANTI FREEZ E THERMOST AT – KM9 - KM 10 CO NDENSER 1 / COND ENSER 2 F AN MOTOR CO NTACTOR
– B1 5 HO T WATER CO IL ANTI FREEZ E THERMOST AT – KM1 1 - KM12 COMPRESSOR -MG 11 - MG12 CO NTACT OR
– B1 6 FIRE THERMOSTAT – KM2 1 - KM22 COMPRESSOR -MG 21 - MG22 CO NTACT OR
– B1 7 - B18 GAS MANIFOLD MINIMUM GAS PRESSURE SWITCH
– B1 9 - B20 BLOWER FAN MOTOR -MS1 - MS2 STOPTHERM
– B2 1 - B22 GAS MANIFOLD SMOKE EXTRACTION AIR PRESSURE SWITCH
– B2 3 - B24 EXTR ACTION FAN MOTOR -ME1 - ME2 STOPTHERM
– B2 5 - B26 ELECTRIC BATTERY -E1 - E2 SAFETY KLIXON
– B2 7 ELECTRIC BATTERY -E3 SAFETY KLIXON
– B2 8 CI RCULAT IO N PUMP -MP1 MO TO R STOPTHERM
– MC1.2 CO NDENSER -MC1 - MC2 F AN MOT OR
– MC3.4 CO NDENSER -MC3 - MC4 F AN MOT OR
– B2 9 - B30 GAS MANIFOLD AIR FLOW RATE SAFETY KLIXON – ME1 - ME2 EXTRACTION FAN MOTOR -ME1 - ME2
– B3 2 - B33 GAS MANIFOLD FLASHBACK SAFETY KLIXON – MG11 - MG 12 CO MPRESSOR -MG 11 - MG12
– B4 1 - B42 CO MPRESSOR -MG11 - 12/-MG21 - 2 2 HI GH PRESSURE SAF ETY SW IT CH – MG21 - MG 22 CO MPRESSOR -MG 21 - MG22
– B4 5 - B46 GAS MANIFOLD 1/ GAS MANIFOLD 2 REGULATION KLIXON – MR1 ECONOMISER DAMPER MOTOR
– B5 1 - B52 CO MPRESSOR -MG11 - 12/-MG21 - 2 2 LO W PRESSURE SAF ET Y SWIT CH – MR2 BLOWER DAMPER MOTOR
– MR3 NEW AI R DAMPER MOTOR
– B6 1 - B62 CO MPRESSOR -MG11 - 12/-MG21 - 2 2 HI GH PRESSURE CONTROL SWITCH – MR4 EXTRACTION DAMPER MOTOR
– B7 1 - B72 CO NDENSER -MC1 - MC2 F AN MO TOR MOTOR STO PT HERM – MR6 BY-PASS DAMPER MOTOR
– B7 3 - B74 CO NDENSER -MC3 - MC4 F AN MO TOR MOTOR STO PT HERM – MS1 - MS2 BLOWER FAN MOTOR -MS1 - MS2
– B8 11 - B812 SCROLL COMPRESSOR -MG11 - 1 2 PROTECTION MODULE – Q1 - Q2 BLOWER FAN MOTOR -MS1 - MS2 PROTECTION
– B8 21 - B822 SCROLL COMPRESSOR -MG21 - 2 2 PROTECTION MODULE – Q5 - Q6 EXTRACTION FAN MOTOR -ME1 - ME2 PROTECTION
– Q9 CO NDENSER -MC1 - MC2 F AN MOT OR PROT ECTION
– B9 1 - B92 CO MPRESSOR -MG11 - 12/-MG21 - 2 2 PRESSU RE SWITCH 4/20mA – Q10 CO NDENSER -MC3 - MC4 F AN MOT OR PROT ECTION
– Q11 - Q12 CO MPRESSOR -MG 11 - MG12 PROTECTION
– Q21 - Q22 CO MPRESSOR -MG 21 - MG22 PROTECTION
BCD CO NDENSER CO IL
BEC HO T WAT ER CO IL
BEG CHI LLED WATER COIL
BEV EVAPORATOR COIL
– BG 10 HYG IENE PRO BE – QF1 PRIMARY CIRCU IT PROTECTION -T1
– BH1 0 REG ULATI ON HYGROMET RY PROBE – QF2 PRIMARY CIRCU IT PROTECTION -T2
– BH1 1 EXTERNAL HYGROMETRY PROBE – QF3 PRIMARY CIRCU IT PROTECTION -T3
– BT 10 REG ULATION TEMPERAT URE PROBE
– BT 11 EXTERNAL TEMPERATURE PROBE – QG MAIN SWITCH
– BT 12 BLOWER TEMPERATU RE PROBE
– BT 13 CO LD WATER TEMPERAT URE PROBE – QE1-2-3 HEATER -E1 - E2 - E3 PRO TECTI ON
– BT 14 CO NDENSER 1 SPEED REG ULATION TEMPERAT URE PRO BE