EasyManua.ls Logo

Lennox iComfort M30 - Smart Away Feature Explained; Smart Away Fences; Transition and Away Set Points

Lennox iComfort M30
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
Table 5. Advanced Settings
MENU SETTING (default is bold) Notes:
VENTILATION SETTINGS
Ventilator Type: ERV or HRV
VENTILATION CONTROL MODE (VCM): ASHRAE or Timed
NOTE: Thermostat ventilation rate parameter are to be adjusted only after the HRV/ERV set up is completed and the CFMs are known. Once
the thermostat’s CFMs are adjusted they are used with the thermostat’s timer algorithm to determine how long to run the HRV/ERV.
VCM = TIMED
Ventilation Minutes Per Hour Default is 20 minutes. Range is 0 to 60 minutes
Ventilation Rate Default is 130 CFM. Range is 20 to 500 CFM
Ventilation High Outdoor Temperature Limit Default is 100F. Range is 60F to 115F.
Ventilation Low Outdoor Temperature Limit Default is 0⁰F. Range is -20⁰F to 55⁰F.
Ventilation High Outdoor Dew Point Limit Default is 55⁰F. Range is 45⁰F to 80⁰F.
VCM = ASHRAE and
Ventilation Outdoor Condition
Override is set to ENABLED.
NOTE: In this mode the thermostat can
assist the installer by validating
the ventilation CFMs are capable
of meeting the ASHRAE required
ventilation volumes, but the
thermostat has no ability to control
CFM from the HRV/ERV.
Ventilation Rate Default is 500 CFM. Range is 20 to 500 CFM.
Ventilation High Outdoor Temperature Limit Default is 100F. Range is 60F to 115F.
Ventilation Low Outdoor Temperature Limit Default is 0⁰F. Range is -20⁰F to 55⁰F.
Ventilation High Outdoor Dew Point Limit Default is 55⁰F. Range is 45⁰F to 80⁰F.
ASHRAE Compliance Check
Yes or No: Current settings comply with
ASHRAE 62.2.
ASHRAE Inltration Credit Default is 0 CFM. Range is 0 to 200 CFM.
ASHRAE house oor area serviced by this
ventilator
Default is 2500 square feet. Range is 500 to
5000 square feet.
ASHRAE Number of Bedrooms Default is 3. Range is 1 to 10.

Other manuals for Lennox iComfort M30