6+05:03:12.353; ENC_MGT; can_manager; 04; M0:Message 2
6+05:03:14.780; ENC_MGT; can_manager; 04; M0:Message 3
0+06:58:00.622 M0 GEM> logdumpnv new 2
6+05:03:14.780; ENC_MGT; can_manager; 04; M0:Message 3
6+05:03:12.353; ENC_MGT; can_manager; 04; M0:Message 2
0+06:58:48.320 M0 GEM>
poweroffdrive
Powers off the drives within the specified bays.
Syntax:
poweroffdrive <drives>
drives
Takes the form of a comma separated list of drive bays that are to be powered off. Specifying “all of the drive bay causes all drives to be powered down.
Example:
0+06:55:42.222 M0 GEM> poweroffdrive 0
0+06:55:43.831 M0 GEM> poweroffdrive 1,2,3,4,5,6
0+06:58:00.622 M0 GEM> poweroffdrive all
powerondrive
Powers on the drives within the specified bays.
Syntax:
powerondrive <drives>
drives
Takes the form of a comma separated list of drive bays that are to be powered on. Specifying “all of the drive bay causes all drives to be powered up.
Example:
0+06:55:42.222 M0 GEM> powerondrive 0
0+06:55:43.831 M0 GEM> powerondrive 1,2,3,4,5,6
0+06:58:00.622 M0 GEM> powerondrive all
report_faults
Outputs a summary of the all the faults currently detected by the enclosure firmware.
Syntax:
report_faults
Example:
0+06:55:42.222 M0 GEM> report_faults
----------------------------------------------------------------------
Canister Manager faults
Canister 0 Faults:
...
Power Manager faults
No faults
----------------------------------------------------------------------
0+07:11:44.029 M0 GEM>
reset_saved_zone_info
When saved SAS zone settings are enabled, this command restores the default SAS zoning configuration for
the product. If saved zone settings are not enabled, this command has no effect.