Table 13. Ops Panel LED States (continued)
System Power
(Green/Amber)
Module
Fault
(Amber)
Location
(Blue) (not
used)
LED
Dis-
play
Associated LEDs/
Alarms
Status
On Off
X Power on, all functions good
On On
X
PCM fault LEDs,
fan fault LEDs
Any PCM fault, fan fault, over or under
temperature
On On
X
SBB module LEDs Any SBB module fault
On On
X No module LEDs Enclosure logical fault
On
Flash X Module status LED
on SBB module
Unknown (invalid or mixed) SBB
module type installed, I2C bus failure
(inter-SBB communications), JBOD
VPD configuration error
On
Flash X
PCM fault LEDs,
fan fault LEDs
Unknown (invalid or mixed) PCM type
installed or I2C bus failure (PCM
comms)
On
X Array in failed or
degraded state
Drive failure has occurred causing loss
of availability or redundancy
On
X Array in impacted
state
Arrays operating background function
On
Flash X
SES state S1 Enclosure ID setting different from
"start of day" setting
X Flash Enclosure identification or invalid ID
selected
Operator’s Panel LEDs (5U Enclosures)
The operator’s (ops) panel (see Figure 58 “Ops Panel LEDs on page 57) displays the aggregated status of
all the modules.
56
Lenovo Storage D1212/D1224/D3284Hardware Installation and Maintenance Guide