Multiple enclosures may be connected together using SAS Y-cables, up to a maximum of 192 SFF/96 LFF
drives or 8 enclosures. An example configuration is shown as below.
Figure 47. Multiple 12G Enclosures with Y-cable
One of the basic configurations is multiple enclosures connected to single or dual host adapters shown as
below.
Notes: The SAS zoning profile in Storage D3284 firmware (version 5.0.0.17) is not supported and the
following rules need to be considered:
One host can access the drives in the JBOD ESMs at any time. See Figure 48 “Single host with single host
adapter- Multiple 5U Enclosures” on page 45 and Figure 49 “Single host with dual host adapters- Multiple
5U Enclosures” on page 45.
One or more RAID adapters in the host can access the drives in the JBOD ESMs. Clustering is not
supported in this condition.
One or more non-RAID adapter (HBA) in the host can access the drives in the JBOD ESMs. Clustering is
supported in this condition. See Figure 49 “Single host with dual host adapters- Multiple 5U Enclosures”
on page 45 and Figure 50 “Dual Host Multiple 12G 5U Enclosures” on page 46.