Toinstalltheintrusionswitch,dothefollowing:
1.Removeallexternalmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,
disconnectallpowercordsfromelectricaloutletsanddisconnectallcablesthatareconnectedto
theserver.
2.Prepareyourserver.See“Removingorextendingtheserverfromtherackcabinet”onpage61.
3.Removetheservercover.See“Removingtheservercover”onpage61.
4.Touchthestatic-protectivepackagethatcontainstheintrusionswitchtoanyunpaintedsurfaceonthe
outsideoftheserver.Then,taketheintrusionswitchoutofthepackage.
5.Pressthetab1outwardasshownandthenlowertheintrusionswitchuntilitissecuredinthesocket.
Figure75.Installingtheintrusionswitch
6.Connecttheintrusionswitchcabletotheintrusionswitchconnectoronthesystemboard.See“System
boardcomponents”onpage36.
Whattodonext:
Toworkwithanotherpieceofhardware,gototheappropriatesection.
Tocompletetheinstallation,goto“Completingthepartsreplacement”onpage152.
Removingtheintrusionswitch
Attention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”
onpageiii
and“Guidelines”onpage59.
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
computerforreference.
Chapter6.Replacinghardware107