EasyManua.ls Logo

Lenovo ThinkSystem SR950 - Page 374

Lenovo ThinkSystem SR950
390 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
on page 56
CAUTION:
Make sure that all server power cords are disconnected from their power sources before performing
this procedure.
Before you remove an upper storage interposer:
1. Remove the front cover. See “Remove the front cover” on page 322.
2. Remove the upper compute tray or storage tray. See “Remove a compute tray” on page 305 or
“Remove a storage tray” on page 375.
3. If you removed a compute tray and it has one or more compute system boards installed or a system
board filler, remove the system boards or system board filler. See “Remove a system board” on page
309.
4. Turn the tray upside down and remove the upper fan cage. See “Remove a fan cage (upper tray)” on
page 314.
Complete the following steps to remove an upper storage interposer.
Watch the procedure. A video of the installation process is available:
YouTube
Youku
Figure 118. Upper storage interposer removal
Step 1. Disconnect all power and data cables from the storage interposer.
Step 2. Slide the RAID card forward to disconnect the RAID card from the storage interposer; then, rotate
the RAID card upward. (Leave the three cables connected to the RAID card.)
Step 3. Remove the screw securing the storage interposer in place.
Step 4. Slide the storage interposer to the left and remove it from the tray.
370
ThinkSystem SR950 Setup Guide

Table of Contents