Appendix
8-4
L
_^ONMObk
Code NoteName
C0068
*
Operating status for:
Bit 82XX 8200 vector 93XX
C
0
0
6
8
O
p
e
r
a
t
i
n
g
s
t
a
t
u
s
f
o
r
:
82XX
8200 vector
93XX
0-3 Operating fault (TRIP)
The 10th digit of the LECOM fault number (see C0161 to C0164) is displayed.
Example: TRIP OH = 5 (LECOM no. = 50)
9
3
X
X
(P2102)
4-7 Last communication error
0= Nofault
1 = Check sum error
2 = Protocol frame error
3= Reserved
4 = Invalid code number
5 = Invalid variable
6 = No access permission
7 = Telegram processing interrupted by a new telegram
15 = General fault
8 Ctrl. enable
0 = no controller enable
1 = Controller enable
9 Qmin (f
d
f
dQmin
)
0 = Qmin not active
1= Qminactive
FREE; fig C0150.Bit 5
Default setting: Qmin (f
d
f
dQmin
)
0 = Qmin not active
1= Qminactive
10 Direction of rotation
0 = CW rotation
1 = CCW rotation
Reserved
11 IMP (pulse inhibit)
0 = Pulses to power stages
inhibited
1 = Pulses for power stages
enabled
FREE; display of C0150 bit 1
Default setting: IMP (Pulse inhibit)
0 = Pulses to power stages inhibited
1 = Pulses for power stages enabled
12 QSP (quick stop)
0 = QSP not active
1= QSPactive
Reserved
13 I
max
(current limit reached)
0 = Current limit not
reached
1 = Current limit reached
FREE; display of C0150 bit 2
Default setting: I
max
(Current limit reached)
0 = Current limit not reached
1 = Current limit reached
14 f
d
=f
dset
(Act. frequency =
Frequency setpoint)
0= f
d
<> f
dset
1= f
d
= f
dset
FREE; display of C0150 bit 4
RFG on = RFG off
(Ramp-function generator input = ramp-function generator output)
0 = HLG on <> HLG off
1 = RFG on = RFG off
15 TRIP (fault)
0 = No error
1 = Fault occurred
LECOM format: VH
C0125
*
LECOM baud rate
(P82XX)
(P93XX)
0 9600 Baud (Factory setting)
1 4800 Baud
2 2400 Baud
3 1200 Baud
4 19200 Baud
Transmission rate for LECOM-A/B/LI in bit/s (= baud).
LECOM format: VD
C0127 Selection Setpoint
selection
(P821X, P822X, P824X)
(P2102)
0 Absolute setpoint selection
1 Normalized setpoint selection
LECOM format: VD