Commissioning
5-7
48XX/49XXSHB0399
With the configurations C005 = -X2- or -X3- and activated angle controller
(C254 > 0), the drive will be decelerated to speed = 0 and angle-controlled
(drift-free). The drive can thus generate its maximum torque (independently of the
current limit C022, C023).
Code Name
Possible settings
Lenze Selection Info
C105 Decele-
ration time
for quick
stop
0.00s 0s {0.01s} 1s
1 s {0.1s} 10s
10 s {1 s} 100 s
100 s {10 s} 990 s
Time referred to the speed change
0...n
max
( Configuration possibilities for the selection of the direction of rotation and
quick stop
Operating
mode
Setpoint to
X1/8
X2/21 X2/22 C041 C042 Direction of
rotation
(View
towards
motor shaft)
Te r mi na l
positive HIGH LOW -0- -0- cw
negative LOW HIGH -1- -0-
C041 and
positive LOW HIGH -1- -0- ccw
C042 display
negative HIGH LOW -0- -0-
he
a
u
pos. / neg. HIGH HIGH -0- / -1- -0- unchanged
X2/21 and
X2/22
pos. / neg. LOW LOW -0- / -1- -1- Quick stop
active
Keypad /
LECOM
positive HIGH/LOW LOW/HIGH -0- -0- cw
C041 and
C042
negative HIGH/LOW LOW/HIGH -1- -0-
determine the
direction of
positive HIGH/LOW LOW/HIGH -1- -0- ccw
quick stop, in
addition LOW
negative HIGH/LOW LOW/HIGH -0- -0-
signal X2/21
and X2/22
activates quick
stop.
pos. / neg. LOW LOW -0- / -1- -1- Quick stop
active