Configuration
UOMu_^MVMO 7-5
Code IMPORTANTPossible settingsNameCode IMPORTANT
InfoSelectionLenze
Name
C009* Device address 1 1 {1} 99 Only for
LECOM
applications
C010 Minimum field
frequency
0.0 0.0 {0.1Hz} 480.0
C011 Maximum field
frequency
820X 50.0 30.0 {0.1Hz} 480.0
821X 50.0 7.5 {0.1Hz} 480.0
30.0 {0.1Hz} 480.0
(Software 2x)
(Software 1x)
822X/824X 50.0 7.5 {0.1Hz} 480.0
C012 Acceleration
time
5.0 0.0 {0.1s} 999.0
C013 Deceleration
time
5.0 0.0 {0.1s} 999.0
C014
¿
Operating mode
820X -0- -0- Linear characteristic V~f
d
with auto
boost
-1- Square characteristic V
~f
d
2
with auto
boost
-2- Linear characteristic V~f
d
with constant
V
min
boost
-3- Square characteristic V
~f
d
2
with
constant V
min
boost
821X/822X
/ 824X
-4- -4- Motor-current control
C015
V/f-rated
frequency
820X 50.0 30.0 {0.1Hz} 960.0
821X 50.0 7.5 {0.1Hz} 960.0
30.0 {0.1Hz} 960.0
(Software 2x)
(Software 1x)
822X/824X 50.0 7.5 {0.1Hz} 960.0