EasyManua.ls Logo

Lenze 8203 - User Manual

Lenze 8203
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
FAST SHIPPING AND
DELIVERY
TENS OF THOUSANDS OF
IN-STOCK ITEMS
EQUIPMENT DEMOS
HUNDREDS OF
MANUFACTURERS
SUPPORTED
LEASING/MONTHLY
RENTALS
ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

Table of Contents

Questions and Answers

  • C
    chenryAug 30, 2025
    Why Lenze Inverter motor does not rotate smoothly?
    • H
      helen96Aug 30, 2025
      If the Lenze Inverter motor isn't rotating smoothly: * The motor cable might be defective, so replace it. * The maximum current settings (C022 and C023) might be too low, so adjust them. * The motor might be underexcited or overexcited, so check the parameter setting.
  • V
    valeriematthewsAug 29, 2025
    How to reduce high current consumption of motor with Lenze Inverter?
    • R
      Russell KnightAug 29, 2025
      If the motor's current consumption is too high when using a Lenze Inverter: * Reduce the setting of C016. * Increase the setting of C015. * Adapt C088 and C091 to the motor data.
  • L
    Lisa GarciaAug 28, 2025
    What causes OC1 short circuit in Lenze Inverter?
    • A
      Aaron OconnellAug 28, 2025
      If your Lenze Inverter displays an OC1 (Short circuit) error, it could be due to: * A short circuit. Find out the cause of the short circuit and check the cable. * Excessive capacitive charging current of the motor cable. Use a motor cable that is shorter or of lower capacitance.
  • H
    Heather HernandezAug 27, 2025
    How to fix Lenze Inverter heat sink temperature too high?
    • M
      Michael DonaldsonAug 27, 2025
      If the heat sink temperature of your Lenze Inverter is too high, consider the following: * The ambient temperature might be too high (Tamb > +40 C or +50 C). Allow the controller to cool and ensure proper ventilation. Also, check the ambient temperature in the control cabinet. * The heat sink might be dirty, so clean it. * The mounting position might be incorrect, so change it.
  • A
    Angie BradfordAug 27, 2025
    What to do if Lenze Inverter shows OOV overvoltage error?
    • L
      Lori JonesAug 27, 2025
      If your Lenze Inverter displays an OOV (Overvoltage) error, it could be due to: * Mains voltage being too high, check the voltage supply. * Feedback or braking operation issues. Try increasing deceleration times. If using brake choppers, check the selection and connection of the brake resistor and increase the deceleration times. * Earth leakage on the motor side. Inspect the motor cable and motor for earth faults, disconnecting the motor from the inverter to do so.
  • W
    wongsherryAug 25, 2025
    Why Lenze Inverter motor does not rotate?
    • C
      Carlos RichardsAug 26, 2025
      If the Lenze Inverter motor isn't rotating, it could be due to several reasons: * The DC-bus voltage might be too low, in this case check the mains voltage. * The controller might be inhibited, so check the operating module. * The setpoint might be zero, so set a proper setpoint. * DC braking or the quick-stop function could be active, so disable them. * If a JOG setpoint is activated but the JOG frequency is zero, set the JOG frequency. * A fault might be indicated (refer to chapter 8.3 for fault details). * The mechanical motor brake might not be released, so release it.
  • C
    Crystal RobertsAug 25, 2025
    What causes faulty auto-TRIP reset in Lenze DC Drives?
    • S
      Stephanie FitzgeraldAug 25, 2025
      If you have a faulty auto-TRIP reset on your Lenze DC Drives, it could be due to more than 8 fault messages in 10 minutes. The solution depends on the specific fault message.

Summary

Safety information

Technical data

Rated data (Operation with 150 % overload)

Lists technical specifications and performance data for 150% overload.

Installation

Mechanical installation

Covers important notes and procedures for physical mounting.

Electrical installation

Details essential steps for connecting the controller electrically.

Commissioning

Configuration

Troubleshooting and fault elimination

Troubleshooting

Covers fault indication and basic troubleshooting steps.

Fault analysis using the history buffer

Explains how to use the history buffer for fault tracing.

Fault indications

Lists and explains various fault codes and their causes.

Reset of fault indications

Details the procedure for resetting fault messages.

Lenze 8203 Specifications

General IconGeneral
BrandLenze
Model8203
CategoryDC Drives
LanguageEnglish