Troubleshooting and fault elimination
8250BA0903 6-1
6 Troubleshooting and fault elimination
Fault Cause Remedy
Green LED is not illuminated No voltage at terminals +U
G
,-U
G
Switch on the mains
Connect the brake unit to the
terminals +U
G
,-U
G
of the
controller
Controller sets pulse inhibit during
braking and indica tes overvoltage
Yellow LED is not illuminated The brake unit is not connected to
the terminals +U
G
,-U
G
of the
controller
Connect the brake unit to the
terminals +U
G
,-U
G
of the controller
Yellow LED is illuminated Brake resistor is not connected Connect brake resistor
Brake resistance too high Use lower-value brake resistor