Configuration
7-8
SHB9300CRV EN 2.0
Create connections
1. Determine the signal source for ARIT2-IN1:
Change to the code level using the arrow keys
Select C0601/1 using
?
or
+
.
Change to the parameter level using PRG.
Select output AIN2/OUT (selection number 55) using
?
or
+
.
–ConfirmusingSH+PRG
Change to the code level again using PRG.
2. Determine signal source for ARIT2-IN2:
Select C0601/2 using
?
.
Change to the parameter level using PRG.
Select output AIN2/OUT (selection number 55) using
?
or
+
.
–ConfirmusingSH+PRG
Change to the code level again using PRG.
3. Parameterise ARIT2:
Select C0600 using
+
.
Change to the parameter level using PRG.
Select multiplication (selection number 3).
–ConfirmusingSH+PRG
Change to the code level again using PRG.
4. Determine signal source for AOUT1:
Select C0431 using
+
.
Change to the parameter level using PRG.
Select output ARIT2-OUT (selection number 5505).
–ConfirmusingSH+PRG
Change to the code level again using PRG.
5. Enter function block ARIT2 in the processing table:
Select C0465 and subcode 8 using
?
Change to the parameter level using PRG.
Enter function block ARIT2 (selection number 5505).
–ConfirmusingSH+PRG
Change to the code level again using PRG.
The sequence of the FB processing is thus determined.