EasyManua.ls Logo

Lenze 9300 - System Speed Monitoring Nmax

Lenze 9300
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
7-271
SHB9300CRV EN 2.0
7.7.3.23 System speed monitoring N
Max
Purpose
Monitores the process.
MONIT
MONIT-N
MAX
MCTRL-N
ACT
C0596
Fig. 7-209 System speed monitoring N
Max
Signal Source Note
Name Type DIS DIS format CFG List Lenze
MCTRL-N
ACT
- - - - - - assignment cannot be changed
MONIT-N
MAX
d - - - - - -
Function
Independentlyofthedirectionofrotation,themax.systemspeed canbeselectedundercodeC0596.
The monitoring is activated if:
l
the actual speed exceeds the limit set under C0596.
l
the actual speed exceeds the value set under C0011 (n
max
) by 200%.
Stop!
l
With active loads (e.g. hoists)ensure, that no torque is generated. Special, system-specific
measures are required.
l
In the event of a failure of the actual speed encoder it cannot be guaranteed that the
monitoring will be activated.
Features:
l
LECOM-No.: 200
l
Reaction: TRIP (unchangeable)
Show/Hide Bookmarks

Table of Contents

Other manuals for Lenze 9300

Related product manuals