Function
l
The filter time constant is selected under C1659.
This setting is valid for SPC2-STAT1 ... SPC2-STAT4.
Assignment of code and filter time constant
Code Value Filter time constant
C1659
0 Off
C
1
6
5
9
1 1ms
2 2ms
4 4ms
8 8ms
16 16 ms
Note!
The correct setting can only be found by testing. In general:
The lower the resolution of the actual position encoder and the lower the travel speed, the higher the
filter time constant.