Function block library
7-42
SHB9300CRV EN 2.0
ARITPH4
+
-
*
/
C1550
x
y
ARITPH4
ARITPH4-OUT
C1552/1
± 2
30
-1
C1552/2
ARITPH4-IN1
ARITPH4-IN2
C1551/1
C1551/2
ARITPH-Modus
Fig. 7-32 Function block ARITPH4
Signal
Source Note
Name Type DIS DIS format CFG List
ARITPH4-IN1 ph C1552/1 dec [inc] C1551/1 3 -
ARITPH4-IN2 ph C1552/2 dec [inc] C1551/2 3 -
ARITPH4-OUT ph - - - -
ARITPH5
+
-
*
/
C1555
x
y
ARITPH5
ARITPH5-OUT
C1557/1
± 2
30
-1
C1557/2
ARITPH5-IN1
ARITPH5-IN2
C1556/1
C1556/2
ARITPH-Modus
Fig. 7-33 Function block ARITPH5
Signal
Source Note
Name Type DIS DIS format CFG List
ARITPH5-IN1 ph C1557/1 dec [inc] C1556/1 3 -
ARITPH5-IN2 ph C1557/2 dec [inc] C1556/2 3 -
ARITPH5-OUT ph - - - -
ARITPH6
+
-
*
/
C1560
x
y
ARITPH6
ARITPH6-OUT
C1562/1
± 2
30
-1
C1562/2
ARITPH6-IN1
ARITPH6-IN2
C1561/1
C1561/2
ARITPH-Modus
Fig. 7-34 Function block ARITPH6
Signal
Source Note
Name Type DIS DIS format CFG List
ARITPH6-IN1 ph C1562/1 dec [inc] C1561/1 3 -
ARITPH6-IN2 ph C1562/2 dec [inc] C1561/2 3 -
ARITPH6-OUT ph - - - -
Function
l
Selection of the arithmetic function with the code ARITPH mode.
l
The function block limits the result (see table)
ARITPH mode Arithmetic function Limitation
C1010=0 OUT = IN1 2
30
-1
C1010=1 OUT = IN1 + IN2 2
30
-1
Show/Hide Bookmarks