Loading...
Function block library
7-135
SHB9300CRV EN 2.0
Example 2 (only for FIX32 format scaling):
Ta s k :
l
C0473/1 = 1000. Write this value to C0011.
Configuration:
l
Connect FEVAN1-IN (C1096) to FCODE-473/1 (19551).
l
Connect FEVAN1-LOAD (C1097/1) to FCODE-471.B0 (19521).
Parameterization:
l
Set C1091 = 11 ( C0011)
l
Set C1092=0 (no subcode)
l
Set C1093 = 1.0
l
Set C1094 = 0.0001 (no decimal place)
l
Set C1095 = 0 (no offset)
The source code has no unit. The standardization factor is omitted.
Calculation:
FEVAN1–IN
ô
1
10000
ô
C1093
C1094
C1095
C0011 [rpm]
Scaling factor
1000
ô
1
10000
ô
1,0
0.0001
0
1000 rpm
Control:
l
Set C0471.B0 = 1 ( 00000001h)so that the data are transmitted to the target code.
Display:
l
C0011 displays the value 1000 rpm.
The other formats are calculated according to the following formula:
FEVAN1–IN
ô
C1093
C1094
C1095
x