Technical data
Terminal description
Axis modules
4
l
61
EDS700ACBA EN 5.1
Connection to the DC bus (+U
G
, −U
G
)
X101/X102 Labelling Description
UG+ DC−bus voltage UG+
UG− DC−bus voltage UG−
Open the protection cover only if the device is deenergised!
To open the protection cover, press the lock between the clips of the
cover down using a screwdriver and swivel the protection cover
upwards.
i700SX1012
Terminal data
Conductor cross−section Tightening torque
!
[mm
2
] [AWG] [Nm] [lb−in]
Swivel hook 5.0 44.3 PH 3
X101
X102
Electrical data
UG+
UG−
Rated voltage 565/675 V
Current Up to 40 °C: 120 A
40 ... 55 °C: −2.5 %/K
Polarity reversal
protection
For internal connection: not relevant