Code table
10
Function library
10.20
L
10.20-8
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0013
uSEr
Deceleration time
main setpoint
5.00 0.00 {0.02 s} 1300.00 Reference: f re quency change C0011 ... 0
Hz
• Additional setpoint ð C0221
• Deceleration times t o be activated via
digital signals
ð C0103
^ 10.7-1
C0014
v
Operating mode 2
2 V/f characteristic control V ~ f
(Linear characteristic with constant V
min
boost)
• Commissioning without motor parameter
identification possible
• Benefit of identification with C0148:
^ 10.3-1
3 V/f characteristic control V ~ f
2
(Square-law characteristic with constant V
min
boost)
Improved smooth running at low
speed
– V/f ra t e d f re quency (C0015) and slip
(C0021) are calculated and stored.
They do not have to be entered
4 Vector control
For initial selection enter the motor data
5 Sensorless torque control with speed limitation
• Torque setpoint via C0412/6
• Speed limit ation via setpoint 1 (NSET1-N1), if
C0412/1 is a ssigned, if not via max. frequency
(C0011)
and identify the motor parameters with
C0148
Otherwise commissioning is not
possible
C0015
uSEr
V/f rated frequency 50.00 7.50 {0.02 Hz} 960.00 • C0015 is calculated a nd stored under
C0148 when the motor parameters are
identified
• Settings applies to all possible mains
voltages
^ 10.3-3
^ 10.3-8
C0016
uSEr
V
min
boost à 0.00 {0.01 %} 40.00 à Depending on the controller
Setting applies to all mains voltages
permitted
^ 10.3-3
C0017 Frequency
threshold Q
min
0.00 0.00 {0.02 Hz} 650.00 Programmable frequency threshold
• Reference: Setpoint
• Signal output configuration under C0415
C0018
v
Chopper frequency 2
0 2kHzsin
General rule:
The lower the cho
er fre
uenc
^ 10.4-3
1 4kHzsin
• the lower the power loss
• the hi
her the noise
eneration
2 8kHzsin
• the better the smooth running quality
Medium-fre
uenc
motors are onl
3 16 kHz sin
low noise generation
allowed to b e operated at 8 kHz sin or
16 kHz sin (C0018 = 2 or 3)!
C0018 Chopper frequency 6
0 2kHzsin
General rule: ^ 10.4-3
v
(only 8200 vector
1 4kHzsin
The lower the chopper frequency
15 ... 90
W)
2 8kHzsin
• the lower the power loss
3 16 kHz sin
low noise generation
• the higher the noise generation
•
4 2kHz
Medium-fre
uenc
motors are onl
5 4kHz
allowed to b e operated at 8 kHz sin or
6 8kHz
low power loss
16 kHz sin (C0018 = 2 or 3)!
7 16 kH z
8 1kHzsin
9 ... 11
Reserved
12 1 kHz f_top
low power loss
C0019 Threshold for
automatic
DC-injection brake
(Auto DCB)
0.10 0.00
= not active
{0.02 Hz} 650.00 Holding time ð C0106
Deactivate the automatic DC injection brake
when the minimum frequency limit C0239
is active
^ 10.7-6
C0021 Slip compensation 0.0 -50.0 {0.1 %} 50.0 C0021 is calculated a nd stored under
C0148 when the motor parameters are
identified
^ 10.4-1