U
Fault detection and elimination
Malfunction of the drive
EDK82MV222 DE/EN/FR 9.0
L
NPO
Fault RemedyCause
Motor parameter identification
stops with error LP1
Motor too small compared with rated
device power
DC injection brake active via terminal
Unacceptable drive response
with vector control
various Optimise vector control (
118)
Torque dip in the field weakening
range
various Contact Lenze
Stalling of the motor when
operating in the field weakening
range