Commissioning
Operation with motors from other manufacturers
Entering motor data manually
6
134
EDBCSXA064 EN 3.2
IMPORTANTPossible settingsCode
SelectionLenze/
{Appl.}
DesignationNo.
C0111 Service Code
Fine adjustment − rotor
resistance
50.00 {1 %} 199.99
C0112 Service Code
Fine adjustment − rotor time
constant
50 {1 %} 200
C0113 Service Code
Fine adjustment − magnetising
current (I
sd
)
50 {1 %} 200
C0128 Tau motor 5.0
Thermal time constant of the
motor
214
0.5 {0.1 min} 25.0 For calculating the I
2
x t
disconnection
[C0418] Test Cur.Ctrl 0
Controller adjustment:
136
0 Deactivated Deactivate test mode
1 Activated Activate test mode