Technical data
Electrical data
Interface description
2
61
EDBPM−H505 DE/EN/FR 6.1
2.2.2 Interface description
Note!
ƒ The EPM−H505 operating unit is equipped with the serial
interface MSP.
ƒ The EPM−H507 operating unit is equipped with the serial
interface ASP8.
MSP ASP8
1
14
12
3
4
5
678
h410_013 h310_010
Fig. 2−1 MSP DB25 socket and ASP8 Minidin 8 pole socket
Pin Signal Pin Signal
1 n.c. 1 Rx RS232 IN
2 Tx RS232 OUT 2 Tx RS232 OUT
3 Rx RS232 IN 3 n.c.
4 RTS RS232 OUT 4 RTS RS232 OUT
5 CTS RS232 IN 5 CTS RS232 IN
6 n.c. 6 n.c.
7 Signal GND 7 Signal GND
8 n.c. 8 +5 VCC (reserved)
9 ... 16 Signals are not evaluated
17 n.c.
18 Signal is not evaluated
19 ... 21 n.c.
22 ... 25 Signals are not evaluated
n.c. Not connected