Commissioning
820XBA1097 5-5
Important
-
With the setting of f
dmin
>f
dmax
the field frequency is limited to f
dmax
.
-
When selecting the setpoint by means of JOG values, f
dmax
acts as limitation.
-
f
dmax
is an internal standardization variable:
- Use the LECOM interface only for important modifications, when the controller is
inhibited.
-
Observe the maximum motor speed!
-
f
dmin
is only effective under the following conditions:
- With analog setpoint selection.
- With the motor potentiometer function ”DOWN.
Special features
-
With field frequencies f
d
>240Hz:
- The overcurrent switch-off can be activated.
fd
C011
(fdmax)
C010
(fdmin)
0 % 100 %
K35.0062