Configuration
7-8 820XBA1097
Code IMPORTANTPossible settingsNameCode IMPORTANT
InfoSelectionLenze
Name
C099*
Software version Only display
820X 82 1x(Software 1x)
821X 82 2x(Software 2x)
82 1x(Software 1x)
822X/824X 82 1x(Software 1x)
C105 Deceleration
time quick stop
821X/822X/824
X
5.00 0.00 {0.01s} 999.00
C106
Holding time for
autom. DC
injection brake
820X 0.00 0.00 {0.01s} 50.00
821X/822X
824X
0.02 0.00 {0.01s} 999.00
C108*
Gain (C111)
820X 220 0 {1} 255
821X 128 0 {1} 255
822X/824X 128 0 {1} 255
C111
§
Monitor signal -0- -0- Field frequency
-1- Controller load
-2- Motor current
-3- DC-bus voltage