Electrical installation
Preparations
Integrated PE conductor connection
6
l
103
EDS700ACBA EN 5.1
6.5 Preparations
When the mechanical installation has been completed, the electrical wiring starts with
the creation of the integrated electrical connections:
6.5.1 Integrated PE conductor connection
How to proceed:
ƒ Use the swivel hook to establish the PE conductor connection of the devices.
Loosen the screws
Turn the swivel hook into the right position
Fasten the screws
ƒ At the left and right device of an installation row, attach the PE connection twice
conforming to standards.
ƒ Then attach the shield connection sheet.
i700A00x
Terminal data
Conductor cross−section Tightening torque
!
[mm
2
] [AWG] [Nm] [lb−in]
Swivel hook + 2.5 22.1 PH 2