Technical data
Rated data
Supply modules
4
l
34
EDS700ACBA EN 5.1
4.2.3 Supply modules
Basics of the rated data
Mains Voltage Voltage range Frequency range
U
Lrated
[V] U
Lrated
[V] f [Hz]
3/PE AC 400 320 − 0 % ... 440 + 0 % 45 − 0 % ... 65 + 0 %
3/PE AC 480 432 − 0 % ... 528 + 0 % 45 − 0 % ... 65 + 0 %
Mains Vol ta
g
e Volta
g
e ran
g
e Fre
q
uenc
y
ran
g
e
Voltage
U
DC
[V]
Voltage
range
U
DC
[V]
Frequency
range
f [Hz]
2/PE DC 565 455 − 0 % ... 620 + 0 %
2/PE DC 675 540 − 0 % ... 746 + 0 %
Input data
Voltage Frequency current [A]
Number of
phases
[V] [Hz] up to +40 °C
up to +55 °C
E70ACPSx0304x 400/480 50/60 24.5/24.5 15.3/15.3 3
E70ACPSx0604x 400/480 50/60 49.0/49.0 30.6/30.6 3
Temperature in the control cabinet