Product description
Device features
3
Ò
19
EDSMDAG EN 2.0
3.2 Device features
Device feature EMDAG2... EMDAG3... EMDAG4... EMDAG5...
Power range
(Peak Power)
kW 7.5 ... 60 2.8 ... 5.6 2.8 ... 60 7.5 ... 22
DC/AC inverter 2 ˘ 1 1
DC/DC converter ˘ 1 1 ˘
Approval acc. to ECE R10 l l l l
Degree of protection IP6K9K IP6K9K IP6K9K IP6K9K
Cooling Water / glycol (^ 36)
Mounting type free
12/24−V voltage for maintaining the
control functionality in the case of
mains failure
l l l l
Digital inputs 4 4 4 4
configurable as analog input 2 2 2 2
configurable as frequency input 2 2 2 ˘
Digital outputs 4 4 4 ˘
Resolver connection 2 ˘ 1 ˘
Motor temperature monitoring PT1000, KTY83/110, KTY84/130, thermostat (normally−closed contact)
acc. to DIN44080, PTC acc. to DIN44081
Public CAN l l l l
Baud rate kbps 125 ... 500 125 ... 500 125 ... 500 125 ... 500
Private CAN l l l l
Baud rate kbps 125 ... 1000 125 ... 1000 125 ... 1000 125 ... 500
Operation in generator mode
(optional)
l ˘ l l
Loop−through of HV system l l l ˘
Overload cycle at 1.8 × I
rated
10 s ˘ 10 s 10 s
Overload cycle at 1.5 × I
rated
60 s ˘ 60 s 60 s
Motor speed range rpm −32000 ... 32255 ˘ −32000 ... 32255 −32000 ... 32255
Technology application
Actuator speed l ˘ l l
Switch−off positioning m ˘ m ˘
Absolute positioning m ˘ m ˘
l Included as standard
m Optionally available
˘ Not available