Installation
EMC−compliant installation
Shielding
5
Ò
45
EDSMDAG EN 2.0
5.4.2 Shielding
ƒ The effectiveness of a shielded cable is reached by:
Providing a good shield connection through large−surface shield contact.
Using only braided shields with low shield resistance made of tin−plated or
nickel−plated copper braid.
Using braided shields with an overlap rate > 70 % and an overlap angle of 90 °.
Keeping unshielded cable ends as short as possible.
Use system cables or shielded cables for these connections:
ƒ Motor
ƒ HV on−board supply system
The following connections need not be shielded:
ƒ LV on−board supply system (only PSU)
ƒ 24−V supply
ƒ Digital signals (inputs and outputs).
We recommend to use shielded cables for a cable length from approximately 5 m
on or in environments with strong interferences.
Connection system
Prefabricated cables for the motor connection and the connection to the HV on−board
supply system are provided with cable glands and ensure an optimum connection of the
shield to the vehicle mass. This guarantees an optimum EMC−compliant installation and
the required environmental conditions are met.
ƒ When installing the motor cable and the HV on−board cable, slide the cable gland
into the respective holders and fix it by tightening the mounting bracket.
5.4.3 HV on−board cable
The descriptions in the next chapter regarding shielded motor cables analogously also
apply to the HV mains cables (see next chapter).