EasyManua.ls Logo

Lenze MOBILE DCU PSU

Lenze MOBILE DCU PSU
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
Connections of MOBILE DCU, PSU, DCU PSU
Feedback
5
Ò
56
EDSMDAG EN 2.0
5.6.4 Feedback
X32 and X33 serve to connect feedback systems for servo control and sensors for motor
temperature monitoring.
ƒ Supported feedback system: resolver
ƒ Supported sensors for motor temperature monitoring: PT1000, KTY83/110,
KTY84/130, PTC acc. to DIN 44081, thermostat (normally−closed contact) acc. to
DIN 44080.
Maximally three PTC thermistors may be connected in series.
Monitored: short circuit and cable breakage. Thermostats are not monitored.
Each connection is assigned to a motor connection. The MOBILE DCU assignment is
configurable.
ƒ X32 <=> motor connection X12
ƒ X33 <=> motor connection X13
X32 X33
MOBILE DCU EMDxG2... l l
MOBILE PSU EMDxG3... ˘ ˘
MOBILE DCU/PSU EMDxG4... ˘ l
X32, X33 (M12 female socket A−coding)
EMDAG020d
2
4
6
3
1
8
7
5
1 +Ref
(+OSZ)
5 +COS
2 −Ref
(−OSZ)
6 −COS
3 +Sin 7 +KTY
(+TEMP)
l KTY83/110
l KTY84/130
l PT1000
l PTC (DIN 44081)
l J−Switch NC
4 −Sin 8 −KTY
(−TEMP)
+REF
-REF
+COS
+SIN
-SIN
-COS
+KTY
-KTY
1
2
3
4
5
6
7
8
X32 / X33
KTY
2
4
6
3
1
8
7
5
+
EMDAG035

Table of Contents

Other manuals for Lenze MOBILE DCU PSU

Related product manuals