Technical data
Rated data of the devices for HV on−board supply system 800 V
DC/AC inverter
4
Ò
27
EDSMDAG EN 2.0
4.2.2 DC/AC inverter
DC/AC inverter 7.5 kW 11 kW 15 kW 22 kW 30 kW 60 kW
Input voltage − HV on−board supply system
Rated voltage V DC 800
Voltage range V DC 100...848
Output voltage 3 AC 0V...510V
Output frequency f
out
Hz −599...+599
Switch−off at short−circuit current A 24 36.1 48.1 72.1 96.2 192.3
Continuous operation
Current consumption − HV
on−board supply system
A 9.8 13.5 18.4 26.3 39.2 71
Output power kW 5 7.3 10 14.7 20 40
Output current at
f
out
<5Hz
2 kHz,
permanent
A 8 11 15 21.5 32 58
4 kHz,
permanent
A 6.4 8.8 12 17.2 25.6 46.4
8 kHz,
permanent
A 4.8 6.6 9 12.9 19.2 34.8
16 kHz,
permanent
A 2.4 3.3 4.5 6.5 9.6 17.4
4 kHz auto A 8 11 15 21.5 32 58
8 kHz auto A 7.2 9.9 13.5 19.4 28.8 52.2
16 kHz auto A 4.4 6.1 8.3 11.8 17.6 31.9
Output current at
f
out
>5Hz
2 kHz,
permanent
A 12.8 17.6 24 34.4 51.2 92.8
4 kHz,
permanent
A 10 13.8 18.8 26.9 40 72.5
8 kHz,
permanent
A 7.2 9.9 13.5 19.4 28.8 52.2
16 kHz,
permanent
A 4 5.5 7.5 10.8 16 29
4 kHz auto A 10 13.8 18.8 26.9 40 72.5
8 kHz auto A 8 11 15 21.5 32 58
16 kHz auto A 4.8 6.6 9 12.9 19.2 34.8
Output current for "socket" application (VAC)
f
out
<10Hz, VAC 16 kHz,
permanent
A 2.8 3.9 5.3 7.5 10.6 18.6
f
out
>10Hz, VAC 16 kHz,
permanent
A 5 6.9 9.5 13.5 18.9 34.2