Technical data
Rated data of the devices for HV on−board supply system 800 V
DC/AC inverter
4
Ò
28
EDSMDAG EN 2.0
60 kW30 kW22 kW15 kW11 kW7.5 kWDC/AC inverter
Overcurrent cycle 60s
Operation for 60s with up to 150% of the continuous output current if afterwards a recovery time of 120s with
max. 50% of the continuous output current is observed.
Current consumption − HV
on−board supply system
A 14.7 20.2 27.6 39.5 58.8 106.6
Max. output power kW 7.5 11 15 22 30 60
Max. output
current at
f
out
<5Hz
2 kHz,
permanent
A 12 16.5 22.5 32.3 48 87
4 kHz,
permanent
A 9.2 12.7 17.3 24.7 36.8 66.7
8 kHz,
permanent
A 5.6 7.7 10.5 15.1 22.4 40.6
16 kHz,
permanent
A 3.2 4.4 6 8.6 12.8 23.2
4 kHz auto A 12 16.5 22.5 32.3 48 87
8 kHz auto A 10.4 14.3 19.5 28 41.6 75.4
16 kHz auto A 8 11 15 21.5 32 58
Max. output
current at
f
out
>5Hz
2 kHz,
permanent
A 16 22 30 43 64 116
4 kHz,
permanent
A 12 16.5 22.5 32.3 48 87
8 kHz,
permanent
A 8.8 12.1 16.5 23.7 35.2 63.8
16 kHz,
permanent
A 5.2 7.2 9.8 14 20.8 37.7
4 kHz auto A 14.8 20.4 27.8 39.8 59.2 107.3
8 kHz auto A 12 16.5 22.5 32.3 48 87
16 kHz auto A 8 11 15 21.5 32 58
Max. output current for "socket" application (VAC)
f
out
<10Hz, VAC 16 kHz,
permanent
A 3.4 4.6 6.3 9.0 12.8 22
f
out
>10Hz, VAC 16 kHz,
permanent
A 6.1 8.4 11.4 16.3 22.7 41.2