Technical data
Rated data of the devices for HV on−board supply system 800 V
DC/AC inverter
4
Ò
29
EDSMDAG EN 2.0
60 kW30 kW22 kW15 kW11 kW7.5 kWDC/AC inverter
Overcurrent cycle 10s
Operation for 10s with up to 180% of the continuous output current if afterwards a recovery time of 20s with
max. 120% of the continuous output current is observed.
Current consumption − HV
on−board supply system
A 17.6 24.2 33.1 47.4 70.5 127.9
Max. output power kW 9 13.2 18 26.4 36 72
Max. output
current at
f
out
<5Hz
2 kHz,
permanent
A 12.8 17.6 24 34.4 51.2 92.8
4 kHz,
permanent
A 10 13.8 18.8 26.9 40 72.5
8 kHz,
permanent
A 6.4 8.8 12 17.2 25.6 46.4
16 kHz,
permanent
A 3.6 5 6.8 9.7 14.4 26.1
4 kHz auto A 12.8 17.6 24 34.4 51.2 92.8
8 kHz auto A 12 16.5 22.5 32.3 48 87
16 kHz auto A 9.6 13.2 18 25.8 38.4 69.6
Max. output
current at
f
out
>5Hz
2 kHz,
permanent
A 17.6 24.2 33 47.3 70.4 127.6
4 kHz,
permanent
A 14.4 19.8 27 38.7 57.6 104.4
8 kHz,
permanent
A 10 13.8 18.8 26.9 40 72.5
16 kHz,
permanent
A 6 8.3 11.3 16.1 24 43.5
4 kHz auto A 18 24.8 33.8 48.4 72 130.5
8 kHz auto A 14.4 19.8 27 38.7 57.6 104.4
16 kHz auto A 9.6 13.2 18 25.8 38.4 69.6
Max. output current for "socket" application (VAC)
f
out
<10Hz, VAC 16 kHz,
permanent
A 3.5 4.8 6.6 9.5 13.1 23.2
f
out
>10Hz, VAC 16 kHz,
permanent
A 6.3 8.7 11.9 17 23.7 42.9