Technical data
Control of MOBILE DCU S
Thermal sensor input
4
Ò
35
EDSMDAG EN 2.0
4.4.3 Thermal sensor input
Thermal sensor input Value
Evaluable thermal sensors PT1000, KTY83/110, KTY84/130,
PTC acc. to DIN44081,
thermostat (normally−closed contact) acc. to
DIN44080
Diagnostics option Wire breakage/short circuit
Resistance measuring range W 280 ... 3050
Limit frequency of input filter Hz 10
Resolution Bit 12
4.4.4 CAN bus
Public CAN and Private CAN communicate via a bus cable.
Public CAN, Private CAN
Protocol
Public CAN SAE J1939
Private CAN CANopen
Baud rate kbps 125, 250, 500
Max. cable length
at 125kbps m 250
at 250kbps m 250
at 500kbps m 100
Loop delay of all nodes ns <200