Technical data
General data and operating conditions
4
Ò
24
EDSMDAG EN 2.0
Requirements related to cables for HV on−board supply system and motor
Capacitance per unit length
£2.5 mm
2
/AWG 14 C
core−core
/C
core−shield
<75/150 pF/m
³4 mm
2
/AWG 12 C
core−core
/C
core−shield
<150/300 pF/m
Electric strength
VDE 0250−1 V
0
/V = 0.6/1.0 kV
(V
0
= r.m.s. value external conductor to PE,
V = r.m.s. value external conductor/external conductor)
UL V³600 V
(V = r.m.s. value external conductor/external conductor)
Cable type
Recommendation l RADOX® cable 155S
l Huber & Suhner
EMC
Interference emission ECE R10, Rev. 5 l radiated broad and narrow−band electromagnetic
interferences
l cable−guided transient noise emissions on the supply
cables
Immunity to interference ECE R10, Rev. 5 l Immunity to radiated electromagnetic fields
l Immunity to injected interferences on the supply cables
DC bus EMDAG2... EMDAG3... EMDAG4... EMDAG5...
Rated voltage − HV on−board supply
system
V DC
800 800 800 800
DC−bus capacity mF 240 120 120 80
Discharge resistance kW 300 300 300 573
Capacity against PE nF 9.4 18.8 18.8 9.4
Max. discharge time
(acc. to EN61800−5−1)
s 300 300 300 180
Insulation resistance − DC bus/LV
on−board supply system
MW 10 10 10 >25