Lenze 13466187 EDBTL03 v8 EN, DE, FR, IT, ES 7
Technical data
2.2 Ratings
Type
Power
[kW]
Mains Output Current
Voltage, frequency
Current
[A]
I
N
I
max
for 60 s
[A]
(1)
[A]
(2)
[A]
(1)
[A]
(2)
ETML251X2SFA
0.25
1/N/PE 230 V
(180 V -0%…264 V +0%)
50/60 Hz
(48 Hz -0%…62 Hz +0%)
3.4 1.7 1.6 2.6 2.4
ETML371X2SFA
0.37 5.0 2.4 2.2 3.6 3.3
ETML551X2SFA
0.55 6.0 3.2 2.9 4.8 4.4
ETML751X2SFA
0.75 9.2 4.2 3.9 6.3 5.8
ETML112X2SFA
1.1 12.0 6.0 5.5 9.0 8.3
ETML152X2SFA
1.5 16.0 7.0 6.4 10.5 9.6
ETML222X2SFA
2.2 21 9.6 8.8 14.4 13.2
(1) For rated mains voltage and carrier frequencies 4, 6, and 8 kHz
(2) For rated mains voltage and carrier frequency 10 kHz