5 Applications
The safety sensor only creates square protective fields.
NOTICE
For applications with increased mechanical requirements, device models are available in ver-
sion MLC…/V (see chapter 15 "Order guide and accessories").
5.1 Point of operation guarding
Point of operation guarding for hand and finger protection is typically the most common application for this
safety sensor. In accordance with ENISO13855, resolutions from 14to40mm make sense here. This
yields the necessary safety distance, among others (see chapter 6.1.1 "Calculation of safety distanceS").
Fig.5.1: Point of operation guarding protects reaching into the danger zone, e.g. for cartoners or filling systems
Fig.5.2: Point of operation guarding protects reaching into the danger zone, e.g. for a pick&place robot applica-
tion